You are here:Home > IT Products
Sort By:
Page of 2
ABB PS2 TRACKBALL AND MOUSE CONVERTER, P/N: ABB2005TM ABB PS2 TRACKBALL AND MOUSE CONVERTER, P/N: ABB2005TM

ABB PS2 TRACKBALL AND MOUSE CONVERTER, P/N: ABB2005TM

Any Questions? Feel free to call us at 281-421-1321, or email us at [email protected]

ST/ST F/F Simplex Fiber Coupler ST/ST F/F Simplex Fiber Coupler

Connect two ST fiber simplex patch cables to extend the connection

50ft Cat6 550 MHz Snagless Patch Cable - Blue - Retail-Packaged, P/N: 45130 50ft Cat6 550 MHz Snagless Patch Cable - Blue - Retail-Packaged, P/N: 45130

Snagless design for network adapters, hubs, switches, routers, DSL/cable modems, patch panels and other high performance networking applications.

100ft Cat5E 350 MHz Snagless Patch Cable - Gray - Retail-Packaged, P/N: 45142 100ft Cat5E 350 MHz Snagless Patch Cable - Gray - Retail-Packaged, P/N: 45142

Snagless design for network adapters, hubs, switches, routers, DSL/cable modems, patch panels and other high performance networking applications.

Black Box MultiLink Converter P/N: LB1350A-ST Black Box MultiLink Converter P/N: LB1350A-ST

MultiLink Media Converter P/N: LB1350A-ST

Data Storage Tape, P/N: 4MM-DDS-90 Data Storage Tape, P/N: 4MM-DDS-90

Data Storage Tape, P/N: 4MM-DDS-90

Any Questions? Please feel free to call at 281-421-1321, or email us a [email protected]

LogMessage High Isolation Data Logging System, P/N: LM1000 LogMessage High Isolation Data Logging System, P/N: LM1000

The LogMessage 1000 is equipped with 15 analog inputs and a sampling rate of up to 600 measurements per second. The inputs can be used for data acquisition of mV, mA signals or any type of thermocouple. All inputs have differential and galvanic isolation.

  • 600 Hz sampling rate
  • Analog inputs(mV, mA, thermocouple): 15
  • Analog inputs(mV, mA, thermocouple, RTD): none
  • Analog outputs(mA): none
  • Digital inputs(counter): none
  • Digital outputs: none

LogMessage High Isolation Data Logging System, P/N: LM2000 LogMessage High Isolation Data Logging System, P/N: LM2000

The LogMessage 2000 is equipped with 10 universal analog inputs, one analog output, 12 digital inputs (11 counters) and 17 digital outputs. The device has a range of internal monitoring and control functions that enable it to be used as a data acquisition device as well as an independently operating system for control, automation or monitoring.

  • 600 Hz sampling rate
  • Analog inputs(mV, mA, thermocouple): none
  • Analog inputs(mV, mA, thermocouple, RTD): 10
  • Analog outputs(mA): 1
  • Digital inputs(counter): 12(11)
  • Digital outputs: 17

LogMessage High Isolation Data Logging System, P/N: LM3000 LogMessage High Isolation Data Logging System, P/N: LM3000

The LogMessage 3000 is equipped with 15 analog inputs (600 Hz sampling rate) and 24 synchronous digital inputs (with a time resolution of 1 msec). The device is highly suited to fault analysis as well as to processing digital and analog events.

  • 600 Hz sampling rate
  • Analog inputs(mV, mA, thermocouple): 15
  • Analog inputs(mV, mA, thermocouple, RTD): none
  • Analog outputs(mA): none
  • Digital inputs(counter): 24
  • Digital outputs: 1

LogMessage High Isolation Data Logging System, P/N: LM4000 LogMessage High Isolation Data Logging System, P/N: LM4000

The LogMessage 4000 has an overall sampling rate of up to 10,000 measurements per second and is ideally suited to monitoring functions. Any number of alarm and logic channels can be defined for the 8 analog inputs and 28 digital channels. Any of the 5 digital outputs can be switched irrespective of the current alarm situation.

  • 10000 Hz sampling rate
  • Analog inputs(mV, mA, thermocouple): 8
  • Analog inputs(mV, mA, thermocouple, RTD): none
  • Analog outputs(mA): 2
  • Digital inputs(counter):28 (2)
  • Digital outputs: 5

LogMessage High Isolation Data Logging System, P/N: LM5000 LogMessage High Isolation Data Logging System, P/N: LM5000

The LogMessage 5000 is equipped with 16 universal analog inputs. The inputs are designed to cope with high voltages between individual channels. The LogMessage 5000 has no problem measuring non-isolated signals.

  • 80 Hz sampling rate
  • Analog inputs(mV, mA, thermocouple): none
  • Analog inputs(mV, mA, thermocouple, RTD): 16
  • Analog outputs(mA): none
  • Digital inputs(counter): none
  • Digital outputs: none

LogMessage High Isolation Data Logging System, P/N: LM6000 LogMessage High Isolation Data Logging System, P/N: LM6000

The LogMessage 6000 is equipped with more than 25 analog inputs. The device has an overall sampling rate of up to 1200 measurements per second and can directly acquire, monitor and record data from any thermocouple or RTD sensor.

  • 1200 Hz sampling rate
  • Analog inputs(mV, mA, thermocouple): 15
  • Analog inputs(mV, mA, thermocouple, RTD): 10
  • Analog outputs(mA): 1
  • Digital inputs(counter): none
  • Digital outputs: 1

LogMessage High Isolation Data Logging System, P/N: LM7000 LogMessage High Isolation Data Logging System, P/N: LM7000

The LogMessage 7000 can acquire measurements from up to 30 thermocouples of any type. Configuration software is available to set channels to specific thermocouple types.

  • 1200 Hz sampling rate
  • Analog inputs(mV, mA, thermocouple): 30
  • Analog inputs(mV, mA, thermocouple, RTD): none
  • Analog outputs(mA): none
  • Digital inputs(counter): none
  • Digital outputs: none

LogMessage High Isolation Data Logging System, P/N: LM8000 LogMessage High Isolation Data Logging System, P/N: LM8000

The LogMessage 8000 is equipped with 15 analog inputs and 12 synchronous digital inputs. The device also has 16 digital outputs to control alarms and events.

  • 600 Hz sampling rate
  • Analog inputs(mV, mA, thermocouple): 15
  • Analog inputs(mV, mA, thermocouple, RTD): none
  • Analog outputs(mA): none
  • Digital inputs(counter): 12 (11)
  • Digital outputs: 16

LogMessage High Speed Data Logging System, P/N: LM9000 LogMessage High Speed Data Logging System, P/N: LM9000

The LogMessage 9000 is equipped with 20 analog inputs, 2 analog outputs and 2 digital outputs. The device has an overall sampling rate of up to 1200 measurements per second and can directly acquire, monitor and record data from any thermocouple or RTD sensor.

  • 1200 Hz sampling rate
  • Analog inputs(mV, mA, thermocouple): none
  • Analog inputs(mV, mA, thermocouple, RTD): 20
  • Analog outputs(mA): 2
  • Digital inputs(counter): none
  • Digital outputs: 2

Expert Vibro Data Acquisition and Control System, P/N: Expert Vibro Expert Vibro Data Acquisition and Control System, P/N: Expert Vibro

  • 16 synchronous analog inputs, 50 kHz sampling rate per channel, IEPE, mV, mA sensors selectable via software
  • Integrated comparators for KeyphasorŪ sensors
  • 32 GB data logger memory
  • 4 digital inputs for frequency measurement
  • 4 analog outputs for monitoring
  • 8 digital outputs
  • Display for reading data on-site